PLC-5 , SLC 500 and Legacy HMI Migration to ControlLogix
TDL migrates legacy Allen-Bradley
When to plan the upgrade
Signs it is time
- Rockwell Automation announced the discontinuance of the
PLC-5 platform in June 2017: processors such as the1785-L80B ,1785-L80E and1785-L80C15 are discontinued since 31 July 2017, and the1785-ENET Ethernet module since 18 May 2017. - Spare parts have followed: the
1771-OBD output module was discontinued on 31 January 2021, the1771-P7 power supply on 31 March 2021 and the1784-PKTX DH+ card on 31 March 2022. - SLC 500 processors such as the
1747-L532 ,1747-L542 and1747-L553 were discontinued on 31 March 2024. - MicroLogix 1000, 1100, 1200 and 1500 controllers are discontinued; MicroLogix 1400 is Active Mature.
- RSLogix 5 has reached End of Life, with no more anomaly corrections or functional improvements, and new RSLogix 5 activations stopped being sold on 31 December 2025.
- The release notes of RSLogix 5 v10 and RSLogix 500 v12 list Windows 7 and Windows 10 as supported, but not Windows 11.
Risks of waiting
- Rockwell lists the replacement as an engineering replacement: a different controller that needs program conversion, not a drop-in spare.
- After discontinuation, Rockwell states only that repair and exchange services may be available.
- Remaining stock is limited and regional, and some items run out before their discontinued date.
- Rockwell notes that spare parts, repaired units and engineers who know the
PLC-5 are becoming scarce.
A phased path reduces the risk:
Source: Rockwell Automation product lifecycle pages,
Check your PLC-5 or SLC 500 system
Six questions about the system you run. The findings use Rockwell Automation and Microsoft lifecycle dates; nothing is sent until you choose to send it.
What TDL delivers
PLC & Control System Migration
Allen-Bradley
PLC-5 , SLC 500 and MicroLogix, GE Fanuc, Siemens S5 and HIMA systems upgraded to ControlLogix and CompactLogix; ControlNet and DeviceNet to EtherNet/IP; older HMI/SCADA (RSView32, Citect, PanelView) to FactoryTalk View and PanelView Plus 7. Drive upgrades: DC drives to PowerFlex DC, legacy servo drives to Kinetix. Site survey, code conversion, FAT/SAT and planned cut-over, onshore and on offshore platforms.Industrial Networks & OT Security
EtherNet/IP networks on Stratix managed switches, with redundancy by DLR rings, PRP and HSR. VLAN segmentation, firewalls and secure remote access following IEC 62443 zone and conduit principles. Interfaces to third-party systems over Modbus and OPC UA.
Control Panel Engineering
Control and marshalling panels: design, schematics, fabrication, wiring and factory acceptance testing before shipment. Ex-rated enclosures for hazardous areas.
Project references
| Project | Year | Original system | Upgraded to |
|---|---|---|---|
| JVPC Rang Dong Field – RO Water Maker PLC Upgrade, SLC 500 to CompactLogix 5380 | 2025–2026 | SLC 5/03 with 1746 I/O · HMI on | CompactLogix 5380 with 5069 I/O · existing PanelView relinked over EtherNet/IP |
| Phu My Fertilizer Plant – | 2025 | Allen-Bradley | Redundant ControlLogix 5580 with redundancy modules · FLEX 5000 I/O · PanelView Plus 7 Performance |
| Phu My Fertilizer Plant – Tripper Car Control System Upgrade | 2023 | Allen-Bradley SLC 500 | ControlLogix 5580 XT · Flex XT remote I/O · EtherNet/IP DLR · ControlNet fibre link |
| PV GAS Vung Tau Terminal (Thi Vai) – Loading Arm System HMI Replacement | 2023 | RSView32 HMI on a redundant | FactoryTalk View SE · DH+ to EtherNet/IP converters · new workstations |
| Crown Dong Nai – Cupper Line 1 | 2023 | Allen-Bradley | ControlLogix 5570 · PanelView Plus 7 · PowerFlex 755 and PowerFlex 525 · resolver-based cam module · Guardmaster safety relay |
| JVPC N1 Wellhead Platform – Process Control System Upgrade | 2022 | Allen-Bradley | ControlLogix, FactoryTalk |
| CFT Copper – | 2021 | Allen-Bradley | ControlLogix · PowerFlex DC drives · FactoryTalk View |
| Pha Lai II Thermal Power Plant – Subsidiary Systems Migration | 2020 | Allen-Bradley | ControlLogix / FactoryTalk View SE |
| Vietsovpetro Central Compressor Platform – EDG and Switchgear Control System Upgrade | 2020 | SLC 5/01 (EDG panel) and SLC 5/03 (switchgear monitoring) on | CompactLogix with 1769 I/O · FactoryTalk View SE local station · Modbus TCP to the platform ICSS |
| Phu My Gas Distribution Station – | 2019 | Allen-Bradley | Integrated Control & Safety System: redundant ControlLogix (process control) and AADvance (fire and safety system) |
| Dinh Co GPP – CC01 Turbo Expander Control System Upgrade | 2019 | Allen-Bradley SLC 500 | Redundant ControlLogix, PanelView HMI |
| Crown Dong Nai – Body Maker | 2017 | Allen-Bradley | CompactLogix · PanelView HMI · AC drives |
| Phu My Fertilizer Plant – Fuel Gas Control System Upgrade | 2017 | Allen-Bradley SLC 500 | Redundant ControlLogix with redundant I/O |
| Nestlé Dong Nai – Maggi Line and CIP Control System Upgrade | 2016 | Allen-Bradley SLC 500, Wonderware | ControlLogix · Wonderware · power control system |
| Dinh Co GPP – Gas Compressors | 2016 | Allen-Bradley SLC 500 | Redundant ControlLogix · PanelView HMI |
| Ba Ria Gas Distribution Station – Piping Monitoring Control System Upgrade | 2014 | Allen-Bradley | Redundant ControlLogix · FactoryTalk View SE server and clients · EtherNet/IP DLR remote I/O |
Allen-Bradley end-of-life lookup and replacements
Technical articles
- MicroLogix 1500 faults: FAULT LED, S:6 major error code and how to get back to RUN
PLC-5 to ControlLogix Migration: Converting the Program, Keeping or Replacing 1771 I/O, and What the Tool Won't Do- Upgrade Paths for Legacy Allen-Bradley Systems: SLC 500, MicroLogix, 1768, PanelView, FLEX I/O, ControlNet
- CompactLogix
1769-L31 , L32E, L35E, L23E end of life — migration path to 5370/5380
Frequently Asked Questions
Can the existing PLC-5 or SLC 500 I/O be kept?
Often yes. Depending on the plant, the existing I/O can stay for a first phase and be connected to the new ControlLogix controller, or be replaced with new I/O in the same panel. TDL compares both options during the survey.
How long does the plant need to stop?
The program is converted and tested before the stop, so site work is limited to installation, checks and start-up. The length depends on the I/O count and wiring; past migrations were done within planned shutdowns, including an
Is the HMI migrated as well?
Yes. RSView32, Citect and PanelView applications are migrated to FactoryTalk View SE/ME and PanelView Plus 7 together with the controller.
Still running PLC-5 , SLC 500 or ControlNet?
Speak directly with our engineers. Your RFQ, scope of work or drawings are answered by the engineers who program and commission the systems, from the first review of the existing system to the proposed solution.
Email sales@tdl-ia.com.vn Request a site survey Hotline · Urgent breakdown support