Facility Monitoring (FMCS) and Building Automation for Factories
TDL builds and maintains facility monitoring and control systems (FMCS) and power monitoring systems (PMS) for large factories: HVAC units, compressed air, water and power brought into one SCADA with history, alarms and reports, and kept running under yearly maintenance. In factory and office buildings on the site, the same system does the building automation (BMS) work: HVAC units are controlled on PLCs, not only monitored.
What TDL does
HVAC
Air handling units, outdoor air units and exhaust fans monitored and controlled from the central control room.
Utilities
Air compressors and other utility equipment brought into the SCADA over Modbus, with field signals wired to the PLC.
Project references
Third-party protocols
BACnet/IP and Modbus devices connected through gateways and KEPServerEX.
Controls retrofit
Failed or obsolete PLCs and HMIs in facility panels replaced with CompactLogix and ControlLogix.
Project references
SCADA, history and reports
AVEVA System Platform graphics, historian and automated reports for facility and power data.
Project references
Yearly maintenance
Scheduled preventive maintenance of servers, workstations and PLC stations, backups and on-call support.
Project references
Related services
SCADA & Plant Data Integration
SCADA and HMI on FactoryTalk View SE/ME, FactoryTalk Optix, AVEVA System Platform, AVEVA InTouch HMI (formerly Wonderware InTouch), AVEVA Edge (formerly InduSoft Web Studio), Ignition and N3uron. Thin clients with ThinManager. Historians (FactoryTalk Historian, AVEVA Historian, AVEVA PI System), FactoryTalk Batch, OPC UA, Kepware and MES integration.
Historian & Reporting
Process and equipment history, trends and automated production, energy and facility reports on FactoryTalk Historian, AVEVA Historian and the AVEVA PI System, with data from PLCs and third-party systems over OPC UA, Kepware and Modbus.
Project references
- 2026 – SEHC VD5 – AHU, OAC and Exhaust Fan Control Retrofit on CompactLogixSiemens to CompactLogix · AHU, OAC and exhaust fans · AVEVA System Platform FMCS
- 2025–2026 – SEHC – New Air Compressor Integrated into FMCS SCADAAir compressor into FMCS · Modbus · AVEVA System Platform · central control room
- 2025–ongoing – SEHC – FMCS and PMS Maintenance and IntegrationYearly maintenance · ControlLogix firmware and redundancy · AVEVA System Platform · 37 PLCs
- 2025–2026 – SEHC Admin Building – AHU and OAC Monitoring SystemAVEVA System Platform · BACnet/IP to Modbus TCP · historian and reporting
Technical articles
- What is FMCS? Facility monitoring and control in electronics plants: architecture, BMS, PMS and MES
- Bringing AHUs and air compressors into an FMCS SCADA: BACnet/IP, Modbus, gateways and KEPServerEX
- Power monitoring systems (PMS) in a factory: energy meters, demand, power quality and the data path to SCADA
- What Is SCADA? How It Differs from PLC, HMI and DCS, Plant Architecture and How to Choose a Platform
- What is a process historian? Buffering, deadband and FactoryTalk Historian vs AVEVA PI vs Ignition
- SCADA server redundancy: FactoryTalk View SE, AVEVA System Platform, Ignition and switchover tests
- Modbus RTU and TCP for SCADA: register maps, zero-based addressing, word order, unit IDs and gateways
Frequently Asked Questions
Can existing BACnet or Modbus equipment be connected?
Yes. BACnet/IP and Modbus devices are brought in through gateways and KEPServerEX, as for the AHU, OAC and air compressor integration at SEHC.
Which SCADA platform is used?
The SEHC FMCS and PMS run on AVEVA System Platform. TDL can also build facility monitoring on FactoryTalk, Ignition or N3uron where that fits the plant's standards.
Can the system be covered by maintenance?
Yes. Facility systems can be covered by a yearly maintenance contract with scheduled preventive maintenance of servers, workstations and PLCs, backups and on-call support.
Does TDL do building automation (BMS) for factory buildings?
Yes. In production and office buildings on industrial sites, AHUs, OACs and exhaust fans are controlled on CompactLogix or ControlLogix and supervised from the FMCS SCADA, with packaged equipment connected over BACnet/IP or Modbus, as at SEHC.
Planning facility or utility monitoring for your plant?
Speak directly with our engineers. Send your RFQ, scope of work or drawings: the engineers who program and commission the systems read them and reply, from the first review of the existing system to the proposed solution.
Email sales@tdl-ia.com.vn Request a site survey Hotline · Urgent breakdown support