Ignition SCADA Integrator in Vietnam
TDL Industrial Automation is an Ignition SCADA integrator in Vietnam, listed as Certified (Ignition Certified Integrator) in the integrator directory of Inductive Automation, the maker of Ignition. TDL designs and builds the Ignition system for the plant. TDL proposes Ignition where a plant wants a web-based SCADA with many screens and users, or wants plant data in SQL databases, and connects it to the Allen-Bradley and other PLCs already on site.
What is Ignition SCADA
One server licence, unlimited use
Ignition is licensed per server. One licence covers unlimited clients, sessions, tags and projects, and only the modules a project needs are bought.
Web-based and server-centric
Projects live on one gateway server and are configured from any networked computer through a web browser; Ignition runs on Windows, Linux and macOS.
Modules
Vision and Perspective for operator screens on PCs, tablets and phones, Tag Historian on standard SQL databases, alarming with e-mail and SMS notification, reporting, and built-in drivers for Allen-Bradley, Siemens and Modbus devices.
Ignition Edge and MQTT
Ignition Edge runs on small computers at the machine or skid; MQTT modules from Cirrus Link publish data to brokers and to central Ignition servers.
When TDL proposes Ignition
Many users and screens
Plants that need web clients in offices, control rooms and on mobile devices without a licence per client.
Replacing an old SCADA
Migration of RSView32, Citect or WinCC applications where the plant prefers an open, web-based platform.
Plant data into SQL
Production, energy and quality data stored in SQL databases for reports, dashboards and links to ERP or MES.
Allen-Bradley plants
Direct connection to ControlLogix and CompactLogix controllers already running on site, with the PLC programs kept as they are.
MES, OEE and batch on Ignition
Sepasoft MES modules
Sepasoft, a third-party software company, makes MES modules that run on Ignition: OEE Downtime, Track and Trace, Settings and Changeover, SPC and Batch Procedure for
ISA-88 batches. Where a plant uses or chooses these modules, TDL connects them to the line PLCs. See MES on Ignition (Sepasoft).Background reading
What is OEE, what is MES, and MES on Ignition, and
ISA-88 batch control.
How TDL works
Platform choice
TDL also delivers FactoryTalk and AVEVA (as an AVEVA system integrator), and recommends the platform that fits the plant's standards, licence budget and support needs.
Delivery
Architecture, tag and screen design, PLC interface, historian and reports, testing, commissioning and operator training.
Related services
SCADA & Plant Data Integration
SCADA and HMI on FactoryTalk View SE/ME, FactoryTalk Optix, AVEVA System Platform, AVEVA InTouch HMI (formerly Wonderware InTouch), AVEVA Edge (formerly InduSoft Web Studio), Ignition and N3uron. Thin clients with ThinManager. Historians (FactoryTalk Historian, AVEVA Historian, AVEVA PI System), FactoryTalk Batch, OPC UA, Kepware and MES integration.
Historian & Reporting
Process and equipment history, trends and automated production, energy and facility reports on FactoryTalk Historian, AVEVA Historian and the AVEVA PI System, with data from PLCs and third-party systems over OPC UA, Kepware and Modbus.
Technical articles
- What Is SCADA? How It Differs from PLC, HMI and DCS, Plant Architecture and How to Choose a Platform
- What is a process historian? Buffering, deadband and FactoryTalk Historian vs AVEVA PI vs Ignition
- What is MES: functions, signs you have outgrown Excel, custom software or MES on Ignition
- What is OEE: the A × P × Q formula, a step-by-step shift example, the six big losses and common mistakes
- SCADA server redundancy: FactoryTalk View SE, AVEVA System Platform, Ignition and switchover tests
- OPC DA and DCOM errors after Windows updates: KB5004442, what to check and the path to OPC UA
Frequently Asked Questions
Is TDL an Inductive Automation (Ignition) partner in Vietnam?
Yes. Inductive Automation's integrator directory lists TDL in Ho Chi Minh City as Certified (Ignition Certified Integrator). TDL designs, builds and commissions Ignition systems for plants.
How is Ignition licensed?
Per server. One Ignition licence covers unlimited clients, tags and projects; modules are bought as needed.
Can Ignition read Allen-Bradley controllers directly?
Yes. Ignition has built-in drivers for ControlLogix and CompactLogix, so it can run alongside an existing FactoryTalk or AVEVA system.
When is FactoryTalk or AVEVA the better choice?
When a plant has standardised on that platform or on PlantPAx, or needs features tied to it. TDL compares the options against the plant's standards, licence budget and support needs.
What does an Ignition integrator do?
Inductive Automation makes the Ignition software; an integrator designs and builds the system for the plant: architecture, tag and screen design, PLC interface, historian and reports, testing, commissioning and operator training. TDL is listed as Certified in Inductive Automation's integrator directory.
Considering Ignition for your plant?
Speak directly with our engineers. Your RFQ, scope of work or drawings are answered by the engineers who program and commission the systems, from the first review of the existing system to the proposed solution.
Email sales@tdl-ia.com.vn Request a site survey Hotline · Urgent breakdown support