Many machines and process units still run on PanelView Plus 6, PanelView Plus 1000/1250 or older PanelView terminals that are no longer sold or hard to repair. TDL replaces them with PanelView Plus 7, converts the application and keeps the existing panel and controller program wherever possible.

When to plan the upgrade

Signs it is time

  • PanelView Standard terminals were discontinued between 2012 and 2014.
  • PanelView Plus 6 and PanelView Plus Compact terminals were discontinued in 2021–2022; for some models Rockwell lists no planned replacement.
  • The terminal still talks to the PLC over a serial link: serial applications must be changed to Ethernet when they move to a current PanelView Plus.

Risks of waiting

  • After discontinuation, Rockwell states only that repair and exchange services may be available.
  • Remaining stock is limited and regional, and some items run out before their discontinued date.

Cut-out adapter kits let a PanelView Plus 7 Performance terminal fit the old panel opening; Rockwell states that PanelView Plus 7 Standard terminals must not be installed with these kits, so the terminal type is chosen with the panel in mind.

Source: Rockwell Automation product lifecycle pages and 2711P-AP001A, 2711P-AP004F, 2711P-AP005F, read 24 October 2026. To check your own parts, use the Product Lifecycle Status search on rockwellautomation.com, or ask TDL for a lifecycle review.

What TDL does

Related services

Project references

Service packages

Technical articles

Frequently Asked Questions

Can PanelView Plus 7 fit the old panel cut-out?

For many older PanelView Plus terminals, adapter kits let the PanelView Plus 7 fit the existing cut-out, as on the VinWonders roller coaster console. TDL checks the model and cut-out during the survey.

Is the HMI application rebuilt from scratch?

No. Existing applications are converted and then checked screen by screen; only screens or objects that do not convert are redrawn.

Does the PLC program change?

Usually not. The new terminal reads the same controller tags; only the communication path changes when an old DH+, DH-485 or ControlNet link is replaced with EtherNet/IP.

Replacing obsolete PanelView terminals?

Speak directly with our engineers. Your RFQ, scope of work or drawings are answered by the engineers who program and commission the systems, from the first review of the existing system to the proposed solution.