Breakdown Support and Resident Engineers
Plant breakdowns get priority: troubleshooting on site or remotely, program fixes and replacement Allen-Bradley parts to get production running again. For planned work, TDL provides preventive maintenance and, when the plant needs them, engineers stationed on site.
Service models
On-call breakdown support
Call or message the hotline (phone, WhatsApp, Zalo). Troubleshooting on site or remotely, program fixes and replacement Allen-Bradley parts.
Periodic maintenance
Preventive maintenance on a planned schedule, PLC backup and version control (FactoryTalk AssetCentre) and vibration monitoring.
Resident engineers
TDL engineers stationed at the plant when the plant needs them, supporting operation and maintenance of the control system.
What's included
System health checks
Periodic checks of controllers, networks, servers and backups, with findings and recommendations reported to the plant.
Program, alarm and historian audits
Review of PLC and HMI programs, alarm configuration and historian data to find faults, nuisance alarms and data gaps.
Spare parts and obsolescence planning
Spare-parts lists for critical equipment and a replacement plan for products approaching end of life, before they cause a stoppage.
Operator and maintenance training
Training packages for operators and maintenance engineers on Rockwell Automation and AVEVA systems.
What TDL delivers
Breakdown Support & Lifecycle Services
Line down? TDL troubleshoots on site or remotely, fixes programs and supplies replacement Allen-Bradley parts to get production running again. Also commissioning, preventive maintenance, PLC backup and version control (FactoryTalk AssetCentre), vibration monitoring and training on Rockwell Automation and AVEVA software.
PLC & Control System Migration
Allen-Bradley
PLC-5 , SLC 500 and MicroLogix, GE Fanuc, Siemens S5 and HIMA systems upgraded to ControlLogix and CompactLogix; ControlNet and DeviceNet to EtherNet/IP; older HMI/SCADA (RSView32, Citect, PanelView) to FactoryTalk View and PanelView Plus 7. Drive upgrades: DC drives to PowerFlex DC, legacy servo drives to Kinetix. Site survey, code conversion, FAT/SAT and planned cut-over, onshore and on offshore platforms.
Project references
- 2026 – VinWonders Grand Park – WindStarZ Ride HMI Replacement with PanelView Plus 7Failed ride HMI → PanelView Plus 7 · application recovered and reloaded · no PLC changes
- 2025–2026 – Mega Grand World Hanoi – Sky Drop Ride Compact GuardLogix ReplacementCompact GuardLogix 5370 · ride controller replacement · existing program and safety configuration · remote support
- 2026 – SEHC VD5 – AHU, OAC and Exhaust Fan Control Retrofit on CompactLogixSiemens to CompactLogix · AHU, OAC and exhaust fans · AVEVA System Platform FMCS
- 2025–ongoing – SEHC – FMCS and PMS Maintenance and IntegrationYearly maintenance · ControlLogix firmware and redundancy · AVEVA System Platform · 37 PLCs
- 2023–2024 – P&G Vietnam Dong An – FactoryTalk AssetCentre for LFE Making and Packing LinesFactoryTalk AssetCentre · PLC and HMI backup and version control · audit trail · LFE making and packing lines
- 2019 – PVEP Thang Long – Dong Do Platform – ICSS Maintenance and RepairICSS maintenance · program backup · new workstations · offshore commissioning
- 2014–ongoing – URC Vietnam – Yearly Maintenance of Drives and Control SystemsYearly maintenance since 2014 · 200+ drives of many brands · PLC and SCADA backups
- 2012–ongoing – P&G Vietnam Dong An – Yearly Maintenance and Control System ModificationYearly maintenance since 2012 · making and packing lines · changes and upgrades on demand
Preventive Maintenance Checklist for Allen-Bradley Systems
Service packages
Technical articles
- Logix MSG instruction error codes: .ERR and .EXERR tables, path, cached connections and common fixes
- FactoryTalk Activation Manager errors: host ID, dongles, activation server,
7-day grace period and rehosting - DeviceNet scanner codes
1756-DNB ,1769-SDN : codes 65–99 (72, 77, 78, 91, 92), display, LEDs, Logix tags - ControlNet
1756-CN2 /CNB faults: status display messages, channel A/B indicators, keeper signature, NUT, UMAX 1734-AENTR and1794-AENTR status indicators: meanings, IP address switches, web pages, replacement- MicroLogix 1100 (1763) fault codes: S:6 table (0001, 0012, 0020, 0022), FAULT LED, 1F, clearing, back to RUN
- SLC 500 fault codes (S:6): reading major errors via S:1/13, S:5 and the FLT LED, full code list, clearing
1756-DHRIO status codes: display messages and LEDs for DH+ and Remote I/O, MSG error D0 hex and fixes
Hotline · Urgent breakdown support
Plant stopped? Call or message us. Breakdowns get priority.
Send a support request
Fill in what you know and press the button: your email program opens a message to sales@tdl-ia.com.vn with these details. Nothing is sent until you press Send there. If the plant is stopped, call the hotline as well.
To help our engineers answer, add what you have:
- PLC or controller model and firmware version
- Software and versions (programming, HMI, SCADA)
- Approximate I/O or tag count
- A network sketch or architecture drawing
- Photos of the panels and nameplates
- For spare parts: part numbers and quantities
Drawings and photos can be attached to the email before you send it.
Plant stopped, or need an engineer stationed on site?
Speak directly with our engineers. Send your RFQ, scope of work or drawings: the engineers who program and commission the systems read them and reply, from the first review of the existing system to the proposed solution.
Email sales@tdl-ia.com.vn Request a site survey Hotline · Urgent breakdown support