DeviceNet and ControlNet to EtherNet/IP Migration

DeviceNet and ControlNet still run many machines and process units, but spare parts and diagnostics are getting harder. TDL moves I/O, drives and controllers to EtherNet/IP, plans the cut-over around the plant's shutdown and keeps the process logic unchanged unless the plant asks for improvements.

When to plan the upgrade

Signs it is time

  • The 1756-CNB ControlNet module was discontinued on 31 December 2024 (replacement 1756-CN2).
  • The 1769-SDN DeviceNet scanner was discontinued on 31 December 2025, and the 1747-SDN on 31 March 2024.
  • Rockwell lists the ControlNet solutions for CompactLogix, FlexLogix, SLC and PLC-5 as discontinued, to be replaced with an EtherNet/IP solution.
  • The 1788-CN2DN linking device is End of Life, with a discontinued date of 1 January 2028.

Risks of waiting

  • ControlNet runs at 5 Mbps against 100 Mbps or 1 Gbps for EtherNet/IP, and does not support CIP Motion or CIP Security.
  • After discontinuation, Rockwell states only that repair and exchange services may be available.

Rockwell notes that the nodes do not all have to be migrated at the same time, so the network can move to EtherNet/IP area by area in planned shutdowns.

Source: Rockwell Automation product lifecycle pages and CNET-RM001A, read 24 October 2026. To check your own parts, use the Product Lifecycle Status search on rockwellautomation.com, or ask TDL for a lifecycle review.

What TDL does

Related services

Project references

Technical articles

Frequently Asked Questions

Does the controller have to be replaced?

Not always. Newer ControlLogix and CompactLogix controllers can stay and receive EtherNet/IP modules; older controllers are often upgraded in the same project, as on the Crown Da Nang body maker.

Can the migration be done in phases?

Yes. Lines or units can be moved one at a time while the remaining sections keep running, as on the P&G Dong An packing lines.

What network design does TDL use?

Managed Stratix switches, segmented by line or unit, with DLR rings or redundant networks where the process needs them.