Rockwell Automation (Allen-Bradley) System Upgrades
TDL upgrades running Rockwell Automation systems in Vietnam: Allen-Bradley
What TDL upgrades
PLC-5 and SLC 500 to ControlLogix or CompactLogixProgram conversion and testing, existing I/O kept or replaced according to the survey, DH+, Remote I/O and
DH-485 moved to EtherNet/IP.Project references
Older ControlLogix and CompactLogix controllers
Controllers moved to current ControlLogix and CompactLogix platforms, keeping the application and the plant's tag names.
PanelView and HMI/SCADA
PanelView, PanelView Plus 6 and RSView32 applications converted to PanelView Plus 7 and FactoryTalk View SE.
Project references
ControlNet and DeviceNet to EtherNet/IP
Networks replaced in stages with the I/O, drives and HMI that depend on them.
Redundant controllers
Critical units moved to redundant ControlLogix with redundant I/O where the process needs it.
Drives
DC drives and older AC drives replaced with PowerFlex, legacy servo drives with Kinetix.
How an upgrade runs
1. Survey and installed base
Controllers, I/O, networks, HMI, drives, software versions and program backups recorded and checked against Rockwell's published lifecycle status.
2. Path and scope
Target platform for each system, and what is kept (I/O, wiring, panels) or replaced, written into the scope before pricing.
3. Program conversion and bench test
Programs converted and tested on a bench before site work; the parts a conversion tool does not handle are redone by hand.
4. Panels and FAT
New or modified panels built in TDL's workshop and tested in a factory acceptance test.
5. Cut-over plan
Cut-over planned unit by unit, line by line or in one shutdown, agreed with the plant.
6. Commissioning and handover
Site acceptance, as-built drawings, program backups and training for the plant's engineers.
Related services
PLC & Control System Migration
Allen-Bradley
PLC-5 , SLC 500 and MicroLogix, GE Fanuc, Siemens S5 and HIMA systems upgraded to ControlLogix and CompactLogix; ControlNet and DeviceNet to EtherNet/IP; older HMI/SCADA (RSView32, Citect, PanelView) to FactoryTalk View and PanelView Plus 7. Drive upgrades: DC drives to PowerFlex DC, legacy servo drives to Kinetix. Site survey, code conversion, FAT/SAT and planned cut-over, onshore and on offshore platforms.Industrial Networks & OT Security
EtherNet/IP networks on Stratix managed switches, with redundancy by DLR rings, PRP and HSR. VLAN segmentation, firewalls and secure remote access following IEC 62443 zone and conduit principles. Interfaces to third-party systems over Modbus and OPC UA.
Control Panel Engineering
Control and marshalling panels: design, schematics, fabrication, wiring and factory acceptance testing before shipment. Ex-rated enclosures for hazardous areas.
Project references
| Project | Year | Original system | Upgraded to |
|---|---|---|---|
| JVPC Rang Dong Field – RO Water Maker PLC Upgrade, SLC 500 to CompactLogix 5380 | 2025–2026 | SLC 5/03 with 1746 I/O · HMI on | CompactLogix 5380 with 5069 I/O · existing PanelView relinked over EtherNet/IP |
| Crown Da Nang – Body Maker Control Upgrade to ControlLogix 5580 | 2026 | DeviceNet I/O and drives · PanelView Plus HMI | ControlLogix 5580 · EtherNet/IP · POINT I/O · PowerFlex 755 and PowerFlex 525 · PanelView Plus 7 · IO-Link |
| Phu My Fertilizer Plant – | 2025 | Allen-Bradley | Redundant ControlLogix 5580 with redundancy modules · FLEX 5000 I/O · PanelView Plus 7 Performance |
| PVEP DMDP-A Platform – Offshore Compressor Control System Upgrades | 2023–2024 | ControlLogix on ControlNet, | ControlLogix on EtherNet/IP ( |
| BSR – Steam Turbine Generator (STG) Network & HMI Upgrade | 2024 | ControlNet network, RSView32 HMI | Redundant EtherNet/IP network, FactoryTalk View SE |
| Phu My Fertilizer Plant – Tripper Car Control System Upgrade | 2022–2023 | Allen-Bradley SLC 500 | ControlLogix 5580 XT · Flex XT remote I/O · EtherNet/IP DLR · ControlNet fibre link |
| Phu My Fertilizer Plant – Natural Gas Compressor Control System Migration | 2022–2023 | GE Fanuc PLC and GE SCADA | Redundant ControlLogix 5580 with redundancy modules · 1715 redundant I/O · EtherNet/IP |
| Crown Dong Nai – Cupper Line 1 | 2023 | Allen-Bradley | ControlLogix 5570 · PanelView Plus 7 · PowerFlex 755 and PowerFlex 525 · resolver-based cam module · Guardmaster safety relay |
| CFT Copper – | 2021 | Allen-Bradley | ControlLogix · PowerFlex DC drives · FactoryTalk View |
| Pha Lai II Thermal Power Plant – Subsidiary Systems Migration | 2020 | Allen-Bradley | ControlLogix / FactoryTalk View SE |
| Vietsovpetro Central Compressor Platform – EDG and Switchgear Control System Upgrade | 2020 | SLC 5/01 (EDG panel) and SLC 5/03 (switchgear monitoring) on | CompactLogix with 1769 I/O · FactoryTalk View SE local station · Modbus TCP to the platform ICSS |
| Dinh Co GPP – CC01 Turbo Expander Control System Upgrade | 2019 | Allen-Bradley SLC 500 | Redundant ControlLogix, PanelView HMI |
| Phu My Fertilizer Plant – FAM Conveyor and Libra Packing Control System Upgrade | 2015 | ControlLogix 5555 · RSView32 | ControlLogix 5570 · FactoryTalk View |
| Ba Ria Gas Distribution Station – Piping Monitoring Control System Upgrade | 2014 | Allen-Bradley | Redundant ControlLogix · FactoryTalk View SE server and clients · EtherNet/IP DLR remote I/O |
Allen-Bradley end-of-life lookup and replacements
Current replacement parts (pages for each new catalog number)
Service packages
- End-of-life module / CPU replacement, keeping the existing program
- PanelView Plus 6 → Plus 7 upgrade, migrating the FactoryTalk View ME project
- Legacy HMI/SCADA migration to FactoryTalk, AVEVA or Ignition
Technical articles
- DeviceNet scanner codes
1756-DNB ,1769-SDN : codes 65–99 (72, 77, 78, 91, 92), display, LEDs, Logix tags - ControlNet
1756-CN2 /CNB faults: status display messages, channel A/B indicators, keeper signature, NUT, UMAX 1734-AENTR and1794-AENTR status indicators: meanings, IP address switches, web pages, replacement- MicroLogix 1100 (1763) fault codes: S:6 table (0001, 0012, 0020, 0022), FAULT LED, 1F, clearing, back to RUN
- SLC 500 fault codes (S:6): reading major errors via S:1/13, S:5 and the FLT LED, full code list, clearing
- GuardLogix 5580 and Compact GuardLogix 5380 safety program: safety task, tag mapping, signature, safety-lock
- ControlLogix and CompactLogix firmware updates with ControlFLASH Plus: revisions, order, interruptions
1756-DHRIO status codes: display messages and LEDs for DH+ and Remote I/O, MSG error D0 hex and fixes
Frequently Asked Questions
Can the existing program be reused?
Usually, yes. Rockwell provides conversion of
Do we have to rewire the field I/O?
Not always. Depending on the platform, the existing I/O can stay in service for a period, or be replaced with conversion systems that reuse the field wiring. The survey decides which.
How long does the plant have to stop?
It depends on the scope. TDL plans the cut-over around the plant's shutdown windows; for example, an offshore SLC 500 to CompactLogix upgrade was completed within an
Can only the HMI or only the network be upgraded?
Yes. HMI, network and controller upgrades can be done separately, for example replacing PanelView terminals without changing the PLC.
Planning a Rockwell Automation upgrade?
Speak directly with our engineers. Send your RFQ, scope of work or drawings: the engineers who program and commission the systems read them and reply, from the first review of the existing system to the proposed solution.
Email sales@tdl-ia.com.vn Request a site survey Hotline · Urgent breakdown support