Automation for Gas Processing Plants, Gas Stations and Terminals
Since 2014 TDL has worked on the control and safety systems of PetroVietnam Gas facilities: the Dinh Co Gas Processing Plant, the Phu My and Ba Ria gas distribution stations with the Long Hai and Phuoc Hoa block valve stations, and PV GAS Vung Tau Terminal (Thi Vai). The work covers compressor controls and vibration monitoring, a heater, shut-off valves and closing signals, shutdown systems and ICSS, station SCADA and the loading arm HMI. The projects below are grouped by equipment.
By equipment
Gas compressors and turbo expander
At Dinh Co, the SLC 500 controls of gas compressors
K-01 ,K-02 andK-03 and of the CC01 turbo expander replaced with redundant ControlLogix and PanelView HMI, the turbo expander with Ex-p and Ex-e panels certified for Zone 2 by a DNV (DNV GL) notified body; the obsolete governor air/fuel control of compressorsK-01A ,K-01B andK-02 /03 integrated into the existing ControlLogix system.Vibration monitoring
Allen-Bradley XM vibration monitoring modules on DeviceNet, vibration sensors and Emonitor software supplied and installed for gas compressors
K-1011A /B/C/D at Dinh Co.Project references
Heaters
The controller of heater
E-401B , a water bath heater with two burners at Phu My Gas Distribution Station, upgraded to MicroLogix 1100 in a flameproof and dust-protected local control panel for Zone 1/2 and Zone 21/22, with FAT with the client before shipment.Project references
Shut-off valves and closing signals
The inlet shut-off valve system at Phu My Gas Distribution Station installed and programmed across the AADvance safety system and the ControlLogix process control system; at Ba Ria and the Long Hai and Phuoc Hoa block valve stations, the
HS-804 ,HS-805 andHS-807 closing signals made redundant on 1715 redundant I/O.Shutdown systems and ICSS
The
PLC-5 / HIMA system at Phu My Gas Distribution Station replaced with an ICSS on redundant ControlLogix and AADvance, with new control panels and engineering control desk; at Thi Vai, the firmware of the SC300E shutdown system upgraded, with site tests coordinated with the system vendor's team.Station SCADA and piping monitoring
The
PLC-5 / RSView32 piping monitoring control system at Ba Ria Gas Distribution Station upgraded to redundant ControlLogix with FactoryTalk View SE server and clients and EtherNet/IP DLR remote I/O, reusing and reworking the existing panels.Loading arms
The RSView32 HMI of the loading arm system at Thi Vai replaced with FactoryTalk View SE on new workstations, linked to the existing redundant
PLC-5 controllers through DH+ to EtherNet/IP converters, with SAT and72-hour monitoring after cut-over.
Related services
Integrated Control & Safety Systems (ICSS)
ICSS for onshore and offshore oil & gas facilities and petrochemical plants. Process control on redundant ControlLogix with 1715 redundant I/O, PlantPAx and AVEVA. Safety instrumented systems for SIL 2 and SIL 3 functions on AADvance and Trusted, including ESD and Fire & Gas; safety PLC applications on GuardLogix. Cause & effect implementation and witnessed testing.
PLC & Control System Migration
Allen-Bradley
PLC-5 , SLC 500 and MicroLogix, GE Fanuc, Siemens S5 and HIMA systems upgraded to ControlLogix and CompactLogix; ControlNet and DeviceNet to EtherNet/IP; older HMI/SCADA (RSView32, Citect, PanelView) to FactoryTalk View and PanelView Plus 7. Drive upgrades: DC drives to PowerFlex DC, legacy servo drives to Kinetix. Site survey, code conversion, FAT/SAT and planned cut-over, onshore and on offshore platforms.Control Panel Engineering
Control and marshalling panels: design, schematics, fabrication, wiring and factory acceptance testing before shipment. Ex-rated enclosures for hazardous areas.
Project references
- 2023 – PV GAS Vung Tau Terminal (Thi Vai) – Loading Arm System HMI ReplacementRSView32 → FactoryTalk View SE · DH+ to EtherNet/IP · existing
PLC-5 kept - 2021 – Phu My Gas Distribution Station – Heater
E-401B Controller UpgradeMicroLogix 1100 · water bath heater burner control · flameproof and dust-protected panel · Zone 1/2 and Zone 21/22 - 2021 – Phu My Gas Distribution Station – Inlet Shut-off Valve SystemInlet shut-off valves · AADvance and ControlLogix programming · FactoryTalk View SE
- 2021 – PV GAS Vung Tau Terminal (Thi Vai) – SC300E Shutdown System Firmware UpgradeSC300E shutdown system firmware upgrade · site tests with the system vendor
- 2020 – Ba Ria GDS and LBV Stations – Redundant Closing Signals
HS-804 ,HS-805 ,HS-807 Redundant closing signals · 1715 redundant I/O · ControlLogix and FactoryTalk View SE - 2019 – Phu My Gas Distribution Station –
PLC-5 / HIMA to ICSS UpgradePLC-5 / HIMA → ICSS on ControlLogix and AADvance - 2019 – Dinh Co GPP – CC01 Turbo Expander Control System UpgradeSLC 500 → redundant ControlLogix · Zone 2 Ex panels
- 2017 – Dinh Co GPP – Governor Air/Fuel Control System Replacement for Gas CompressorsGovernor air/fuel control replacement · integrated into ControlLogix
- 2016 – Dinh Co GPP – Gas Compressors
K-01 ,K-02 ,K-03 Control System ReplacementSLC 500 → redundant ControlLogix · PanelView · field instruments - 2015 – Dinh Co GPP – Vibration Monitoring for Gas Compressors
K-1011A /B/C/DAllen-Bradley XM modules · vibration sensors · Emonitor · gas compressors - 2014 – Ba Ria Gas Distribution Station – Piping Monitoring Control System Upgrade
PLC-5 / RSView32 → redundant ControlLogix / FactoryTalk View SE
Frequently Asked Questions
Which gas facilities has TDL worked on?
From 2014 to 2023: the Dinh Co Gas Processing Plant, Phu My Gas Distribution Station, Ba Ria Gas Distribution Station with the Long Hai and Phuoc Hoa block valve stations, and PV GAS Vung Tau Terminal (Thi Vai).
Can TDL build control panels for hazardous areas at a gas facility?
Yes. For the CC01 turbo expander at Dinh Co, Ex-p and Ex-e panels were certified for Zone 2 by a DNV (DNV GL) notified body. For heater
Can old PLC-5 controllers stay in service while the HMI is replaced?
At Thi Vai in 2023 the redundant
Planning work on a gas compressor, heater, shutdown system or station SCADA?