PanelView Plus 6 → Plus 7 upgrade, migrating the FactoryTalk View ME project
Replace the old HMI with PanelView Plus 7, convert and test the ME project, and keep the screens and tags operators are already familiar with.
Scope
- Assessment of the existing ME project (version, tags, alarms)
- Conversion of the project to a version compatible with Plus 7
- HMI replacement, wiring, network configuration
- Test of every screen with operations
- Handover of the new project file + backup
Not included
- Redesigning the interface
- PLC logic changes
What the plant prepares
- Original .mer or .apa project file, or an old terminal from which the application can still be recovered
| Duration | Confirmed after a survey — TDL states the scope and number of days before work starts |
|---|
| Price | Quoted per scope after the survey |
|---|
PanelView Plus 6 has reached end of life, but the FactoryTalk View ME project has not: .apa/.mer files can be converted to a version compatible with PanelView Plus 7 (per the FactoryTalk View ME User Manual, VIEWME-UM004S pp. 57, 180–182, and the PanelView Plus 7 user manuals: 2711P-UM007I pp. 14, 47 for Standard, 2711P-UM008K pp. 14, 65 for Performance). Convert the project and review tags, alarms, screen size and network configuration first, and only then replace the hardware at the plant and test each screen with operations. Two points that are often missed: PanelView Plus 7 Standard requires FactoryTalk View ME version 8.0 or later (2711P-UM007I p. 14), and the adapter kits Rockwell lists for fitting the new terminal into the old panel cutout are for the Performance series only (VIEW-IN002C p. 2) — for the Standard series, measure the cutout before confirming the catalog number.
Related projects: VinWonders Nha Trang – roller coaster HMI migrated from PanelView Plus 1250 to PanelView Plus 7 in the existing cut-out · PVEP DMDP-A platform – compressor control upgrades, PanelView Plus 6 to PanelView Plus 7.
Related services:
PanelView HMI migration Rockwell Automation upgrades
Related technical articles
- Upgrade Paths for Legacy Allen-Bradley Systems: SLC 500, MicroLogix, 1768, PanelView, FLEX I/O, ControlNet
- Legacy HMI/SCADA: What to Replace RSView32, PanelBuilder32, Wonderware, Citect, WinCC and iFIX With — Paths to FactoryTalk, AVEVA and Ignition
- PanelView Plus 7 Shows No Data from the PLC: What to Check
- FactoryTalk View SE vs ME vs FactoryTalk Optix: Differences and Migration Checks
- MicroLogix 1500 faults: FAULT LED, S:6 major error code and how to get back to RUN
All service packages (11)