Home › Technical articles

Đọc bằng tiếng Việt

Stratix 5200 (1783-CMS) switch setup: Express Setup, IP, VLANs, DLR, PRP, backup and replacing a Stratix 5700

TDL Industrial Automation · Last updated:

From 1783-UM012N, 1783-TD002H and 1783-RM001D: the nine 1783-CMS models, the three Express Setup button modes, IP setup in the WebUI or Logix Designer, VLANs and Smartports, DLR, PRP, CIP Sync, saving the configuration, SD card and Swap Drive, and replacing a Stratix 5700 with the Stratix Migration Assistant.

A new Stratix 5200 (1783-CMS…) switch is set up in three moves: the Express Setup button gives it an IP address, the WebUI or Studio 5000 Logix Designer adds VLANs, Smartports and the DLR or PRP settings, and the configuration is then saved and backed up to a file or the SD card. The facts come from Rockwell's user manual 1783-UM012N, technical data 1783-TD002H and migration guide 1783-RM001D. Older Stratix switches: Stratix 5700 / 5400 troubleshooting.

Stratix 5200: first-time setup sequence per 1783-UM012NFour steps from top to bottom: power up and press the Express Setup button (Short Press, Medium Press, Long Press); set the IP address, management VLAN and accounts in the WebUI or Logix Designer; configure VLANs, Smartports, the DLR ring, the PRP RedBox and CIP Sync; save the running configuration to the startup configuration and back it up to a file, the SD card or the Logix Designer project. At the bottom, the order for replacing a Stratix 5700 with a Stratix 5200 per 1783-RM001D: download config.text, convert it with the Stratix Migration Assistant in FactoryTalk Vault, test the new file, load it and reload.Stratix 5200: first-time setup sequence per 1783-UM012N1 · Express Setupbutton on the switchpower-on up to 140 s; EIP Mod and Setup flash greenShort Press 1–5 s: WebUI, the computer gets 192.168.1.1Medium Press 6–10 s: DHCP, WebUI or Logix DesignerLong Press 16–20 s: factory defaults, SD card included2 · IP and accountsWebUI or Logix Designerstatic IP (default), outside the DHCP rangemanagement VLAN, default VLAN 1admin account, CLI password, CIP passwordSubmit: the switch runs the ab-global macro3 · VLANs and ringsbefore devices connectVLANs and a Smartport role per portDLR: ring 1 or 2 on a port pair, WebUI onlyPRP RedBox on 10DN, 20DN: Gi1/1 LAN A, Gi1/2 LAN BCIP Sync: choose the PTP mode4 · Save and back uprunning to startup configSave Configuration: the WebUI does not save by itselfconfig file to a TFTP, SFTP, FTP or HTTP serversync to a 1784-SDHC8 SD card (Swap Drive)Logix Designer: Save/Restore with the projectReplacing a Stratix 5700 with a Stratix 5200 (1783-RM001D)config.textdownloaded fromthe Stratix 5700MigrationAssistantin FactoryTalk Vault,source anddestination SKUsTest the new filecredentials and QoSare not convertedLoad and reloadthrough WebUIBackup & RestoreBased on Rockwell Automation 1783-UM012N-EN-P (10/2025) and 1783-RM001D-EN-P (02/2026), read 15November 2026. Figure: drawn by TDL.
Figure 1: Stratix 5200: first-time setup sequence per 1783-UM012N. On a phone, swipe sideways to see the whole figure.

1. The nine Stratix 5200 catalog numbers

Stratix 5200 switches are Layer 2 fixed switches in 6, 10 and 20-port versions (1783-UM012N p. 13–14). Firmware type, DLR, PRP and CIP Sync depend on the catalog number (1783-TD002H p. 23):

Catalog number Copper ports Combo / SFP Firmware CIP Sync DLR rings PRP, NAT
1783-CMS6B 4 FE 2 GE SFP Base – – –
1783-CMS6P 4 GE 2 GE SFP Full Yes – –
1783-CMS10B 8 FE 2 GE combo Base – – –
1783-CMS10P 8 GE 2 GE combo Full Yes – –
1783-CMS10DP 8 GE 2 GE combo Full Yes 1 –
1783-CMS10DN 8 GE 2 GE combo Full Yes 2 Yes
1783-CMS20DB 18 FE 2 GE combo Base – 1 –
1783-CMS20DP 18 GE 2 GE combo Full Yes 1 –
1783-CMS20DN 18 GE 2 GE combo Full Yes 2 Yes

FE: Fast Ethernet, GE: Gigabit Ethernet. The page also lists -C2 versions of the 10DP, 10DN and 20DB with the same features. All take 12–48 V DC, are open-style IP30 devices and use the 1784-SDHC8 memory card (p. 23–25). Rockwell's product pages showed all nine "Active" on 15 November 2026.

2. Four ways in: Express Setup, WebUI, Logix Designer, CLI

Per the manual's Table 1 (p. 15–16), VLANs, Smartports, PRP, PTP, port security, STP and NAT can be set in the WebUI or in Logix Designer; DLR, ACLs, QoS, REP, MRP and SNMP only in the WebUI. The Cisco command-line interface (CLI) reaches every feature, from the RJ45 or USB-micro console port or a WebUI page (p. 15, 21, 238).

3. Express Setup and the IP address

After power is applied, the power-on sequence can take up to 140 seconds on a Stratix 5200; it is finished when EIP Mod and Setup flash green (p. 30). The recessed Express Setup button has three modes (p. 27–32):

  • Short Press (Setup flashes green, seconds 1–5): port Gi1/3 (Fa1/3 on the B and DB models) blinks. The switch becomes a DHCP server on VLAN 1000 at 192.168.1.254 and gives the computer 192.168.1.1. Setup is finished in the WebUI, then the switch is power-cycled.
  • Medium Press (flashes red, seconds 6–10): the switch asks a DHCP server for an address on VLAN 1; setup must be completed within 10 minutes, in the WebUI or Logix Designer. Logix Designer supports only this mode.
  • Long Press (flashes green and red, seconds 16–20): factory defaults. All configuration files in internal memory and on the SD card are overwritten.

A switch that already has a non-default configuration leaves Short Press with Setup red for 10 seconds (p. 30). Pressing the button under power can cause an arc, and in a hazardous location an explosion (p. 29).

In the WebUI, the first login uses the default credentials printed in 1783-UM012N (p. 32); the setup pages then ask for a new administrator account, a CLI password and the basic settings (p. 33–36). IP assignment defaults to Static, which Rockwell recommends; the address must lie outside the DHCP server's range and the gateway in the same subnet. The management VLAN defaults to 1 and must match the management station's VLAN. Submit runs the global macro ab-global: IGMP snooping and querier, CIP, alarms, syslog, SNMP, Rapid PVST with BPDU Guard, and QoS for CIP and PTP traffic (p. 36, 41).

In Logix Designer the switch is added under Ethernet with the Stratix AOP 19.01.07 or later, at its DHCP address (p. 28, 37–39). The default connection is Input Data; Data adds output tags that can disable ports and, in Run mode, override the WebUI or CLI. The Logix Designer Express Setup page requires a new password, which is also the CIP password (p. 41).

4. VLANs and Smartports

VLAN 1 is the default management VLAN; IDs 1002–1005 are reserved, up to 256 VLANs can be configured, and the WebUI allows 32 SVIs (p. 200). At least one switch port must belong to the management VLAN. Smartport roles go on right after initial setup, before devices are connected; a role that does not match the device can lower QoS or shut the port down (p. 175). Each role needs a VLAN: access for Automation Device, native for Switch for Automation (p. 176).

5. DLR, PRP and CIP Sync

DLR. One ring on the 10DP, 20DB and 20DP, two on the 10DN and 20DN (p. 85). A ring has at least one supervisor and up to 49 ring nodes. In the WebUI the Ring ID is 1 or 2, the ring ports are an adjacent pair N and N+1 with N odd, and supervisor precedence, beacon interval (default 400 µs) and beacon timeout (default 1960 µs) are set (p. 80–81, 85). Rockwell recommends the Multiport Automation Device Smartport role on ring ports (p. 85). Ring design rules: DLR vs PRP.

PRP. Only the 10DN and 20DN (p. 16). The 5200 supports one PRP channel group as a RedBox: Gi1/1 to LAN A, Gi1/2 to LAN B (p. 156). Devices are configured before the PRP cables are connected; the Node and VDAN tables hold 512 entries each (p. 155, 157). PRP infrastructure switches need an MTU of 1506 bytes or more (1783-RM001D p. 18).

CIP Sync. The Full-firmware models support IEEE 1588 PTP (1783-TD002H p. 23). Modes are Boundary, End to End Transparent, Forward, NTP/PTP and End to End Transparent with Multiple VLAN, the last one for PTP over a DLR ring (1783-UM012N p. 224, 227). NTP-PTP needs firmware 17.12.01 or later (1783-RM001D p. 19).

6. Saving, backup and restore

WebUI changes reach only the running configuration until Save Configuration is clicked (1783-RM001D p. 15–16); unsaved changes are lost on restart (1783-UM012N p. 218). Backups:

  • File. Administration > Backup & Restore copies the configuration to or from a TFTP, SFTP, FTP or HTTP location. A configuration copied to the switch takes effect only after a reload (p. 218–219).
  • SD card. Only the 1784-SDHC8 is supported. Sync copies the configuration, the IOS image or both from internal flash to the card, manually, on each change, after a prompt or daily (p. 220–221, 268). The WebUI cannot sync back from the card (p. 220); Logix Designer's SD Flash Sync page lists both directions (p. 222). A locked card cannot be synced (p. 268).
  • Swap Drive. The synced card from a failed switch goes into a powered-off, factory-defaulted replacement, which starts with the original image and configuration (p. 268–269).
  • Logix Designer. Save/Restore moves the configuration between switch, controller project and file (p. 223).

Firmware goes on in Install mode from one .bin file, with about 1.3 GB free, followed by a reload (p. 275).

7. Replacing a Stratix 5700 with a Stratix 5200

On 15 November 2026, Rockwell's product pages showed Stratix 5700 models discontinued on 1 September 2024, each with a Stratix 5200 as Engineering Replacement: 1783-BMS10CGN to 1783-CMS10DN, 1783-BMS20CGN to 1783-CMS20DN, 1783-BMS10CGP to 1783-CMS10DP. All codes: end-of-life lookup.

1783-RM001D lists what changes:

  • Same power terminal blocks and cable orientation; clearance 25.4 mm instead of 50.8 mm (p. 5, 14).
  • 1784-SDHC8 card instead of 1784-SD1; 1783-SFP100T not supported (p. 11).
  • Spanning tree defaults to Rapid PVST+, not MST as on the legacy switches (p. 17).
  • The startup file is startup-config.cfg instead of config.text (p. 16).
  • No FlexLinks, no routed (Layer 3) ports (p. 18–19).

The Stratix Migration Assistant, in FactoryTalk Vault for members of a FactoryTalk Hub organization, converts the 5700's config.text (vlan.dat and dmuser.txt are not needed) once the source and destination catalog numbers are chosen, and writes a log file (p. 27–28). The conversion is not exact: credentials and QoS settings are not carried over. Run Express Setup first, test the new file, then load it through Backup & Restore and reload (p. 28–31).

What we check first

This is TDL's practice, not a Rockwell requirement.

  • We back up the old switch's configuration and photograph the indicators and cabling.
  • We match the catalog number to the job: DLR rings, PRP, CIP Sync, copper speed.
  • We agree the IP plan, management and CIP VLANs with the plant, and keep the static address outside any DHCP range.
  • We check who else writes to the switch: AOP output tags, the WebUI, the CLI.
  • We save the configuration, sync it to the SD card and keep a file copy with the PLC backup.

Stratix work at TDL

TDL Industrial Automation is a System Integrator in the Rockwell Automation PartnerNetwork. On the P&G Cabuyao servo capper, a Stratix 5200 managed switch was configured with a Device Level Ring and Smart Port settings for the connected devices. Our Stratix and VLAN service package ends with network diagrams and configuration files handed over. Related: firewall ports, Rockwell PLC security, industrial networks.

Frequently asked questions

What is the default IP address of a Stratix 5200?

In Short Press Express Setup the switch acts as a DHCP server at 192.168.1.254 on VLAN 1000 and gives the connected computer 192.168.1.1. In Medium Press it takes an address from the plant's DHCP server instead.

Can a Stratix 5200 be set up from Studio 5000 Logix Designer?

Yes, after a Medium Press Express Setup, with the Stratix AOP version 19.01.07 or later. DLR, however, is configured only in the WebUI.

Which Stratix 5200 models support DLR and PRP?

DLR: one ring on 1783-CMS10DP, 1783-CMS20DB and 1783-CMS20DP, two rings on 1783-CMS10DN and 1783-CMS20DN. PRP only on 1783-CMS10DN and 1783-CMS20DN.

Why did my Stratix 5200 lose its settings after a restart?

WebUI changes stay in the running configuration until Save Configuration is clicked, and the switch starts from its startup configuration.

What replaces a Stratix 5700?

Rockwell's product pages name a Stratix 5200 as Engineering Replacement, for example 1783-CMS10DN for 1783-BMS10CGN. The Stratix Migration Assistant converts the old config.text, but credentials and QoS settings are not carried over.

Sources

Read 15 November 2026. This article paraphrases the sources and does not quote them; read the original documents before designing or working on a system.

Related services:
Industrial networks & OT security Rockwell Automation (Allen-Bradley)