Kinetix 300, 350, 6000 and Ultra3000 Servo Drive Migration to Kinetix 5100, 5300 and 5700: Paths and Changes

TDL Industrial Automation · Last updated:

From Rockwell's five migration guides (2198-RM002B to RM006A): which old drive goes to Kinetix 5100, 5300 or 5700; 24 V DC control power, digital inputs, EtherNet/IP, software, which motors and cables can stay; where a listed replacement needs resizing; a checklist before replacement.

Kinetix 300, Kinetix 350, Kinetix 2000, Kinetix 6000/6200/6500, Kinetix 7000 and Ultra3000 are all discontinued. Per Rockwell's product pages (read 27 October 2026): Ultra3000 was discontinued during 2022 (last date 31 December 2022), Kinetix 2000 on 31 December 2022, Kinetix 6000 and Kinetix 7000 on 31 December 2023 (2094-BC07-M05-S on 5 August 2025), Kinetix 300 and Kinetix 350 between 17 July 2023 and 31 July 2024, and the Kinetix 6200/6500 modules between 31 December 2023 and 31 December 2025. A running machine keeps running; the problem is that a failed drive can no longer be replaced with new genuine stock.

Rockwell publishes five migration guides for the main upgrade paths. This article summarises them: which old family goes to which new one, what changes, and what to prepare before a replacement. The replacement for each old catalog number is in the end-of-life lookup.

Old family to new family

Old family Replacement family Guide Control change
Kinetix 6000 (2094, SERCOS) Kinetix 5700 (2198) 2198-RM002B Fiber-optic SERCOS to integrated motion on EtherNet/IP
Kinetix 300 (2097, EtherNet/IP indexing) Kinetix 5100 (2198-E) 2198-RM004C Indexing to PR mode, I/O mode or explicit messaging
Kinetix 350 (2097-…-LM) Kinetix 5300 (2198-C) 2198-RM005B Integrated motion on EtherNet/IP, one port to two
Ultra3000 analog, indexing, DeviceNet (2098) Kinetix 5100 (2198-E) 2198-RM003B Serial/DeviceNet to EtherNet/IP
Ultra3000 SERCOS (2098-…-SE) Kinetix 5300 (2198-C) 2198-RM006A Fiber-optic SERCOS to integrated motion on EtherNet/IP

2198-RM006A states that it covers only Ultra3000 SERCOS drives; analog, indexing and DeviceNet drives are pointed to Kinetix 5100 under 2198-RM003 (2198-RM006A p. 6). Figure 1 on the same page also shows Kinetix 5500, but the body of the guide describes only the path to Kinetix 5300.

For Kinetix 2000, Kinetix 7000 and Kinetix 6200/6500, the publications cited here include no dedicated migration guide. Replacements follow the Rockwell product pages: Kinetix 2000 to Kinetix 5300, Kinetix 7000 to Kinetix 5700. The Kinetix 6200/6500 2094-…-M power modules have inverter ratings of 4, 9, 15, 30 and 49 A 0-pk (2094-UM002I p. 23), equivalent to the 2.8–34.6 A rms Kinetix 6000 modules in Table 9 of 2198-RM002B (p. 24), so that output-current table serves as a reference. The 2094-SE02F and 2094-EN02D control modules have no separate replacement on the Rockwell pages.

Changes that come up on almost every replacement

  • 24 V DC control power. Kinetix 6000 takes its control power from AC; Kinetix 5700 needs a customer-supplied 24 V DC supply for control power, digital inputs and motor brakes (2198-RM002B pp. 12, 19). Kinetix 5300 uses 24 V DC (21.6…26.4 V) at 400 mA, 900 mA or 1.7 A depending on frame, plus brake current (2198-RM005B p. 23). Kinetix 5100 200 V-class drives take control power from one incoming AC phase; 400 V-class drives use 24 V DC (2198-RM004C pp. 16, 28–29).
  • Fewer digital inputs, each assigned a function. Kinetix 6000 has six dedicated inputs; each Kinetix 5700 inverter has four configurable inputs (2198-RM002B p. 20). Kinetix 350 has five fixed inputs; Kinetix 5300 has four configurable sinking inputs (2198-RM005B pp. 19, 21). A machine that uses ENABLE, HOME, both registration inputs and both overtravel inputs needs its wiring reviewed.
  • Dual-port EtherNet/IP. SERCOS moves to EtherNet/IP; the existing controller may be reusable, but the communication module and switches must support EtherNet/IP (2198-RM002B p. 16). Kinetix 5300 has two ports; any external switch must support IEEE-1588 (2198-RM005B p. 27).
  • Software versions. Kinetix 5700 needs Studio 5000 v26.00 or later (2198-RM002B p. 13); Kinetix 5300 needs Studio 5000 v33.00 or later (2198-RM005B p. 46; 2198-RM006A p. 13). Kinetix 5100 is configured in KNX5100C over a mini-USB port, replacing MotionView OnBoard on Kinetix 300 and Ultraware on Ultra3000 (2198-RM004C pp. 34–35; 2198-RM003B p. 41).
  • AC input. Kinetix 5100 and Kinetix 5300 support only a center-grounded wye secondary (2198-RM004C p. 13; 2198-RM005B p. 11; 2198-RM003B p. 13).
  • Safe Torque Off. STO connectors and pinouts differ between old and new drives (2198-RM004C p. 44; 2198-RM005B pp. 33–34). Ultra3000 has no STO; Kinetix 5300 has hardwired STO and needs jumpers when STO is not used (2198-RM006A pp. 17, 53).

Kinetix 6000 to Kinetix 5700 (2198-RM002B)

  • A different bus architecture. The 2094 power rail, slot fillers and LIM are not used; they are replaced by a 2198-Pxxx DC-bus power supply plus inverters (2198-RM002B pp. 13, 16). The contactor enable relay moves from the IAM to the DC-bus supply (CED connector) and must be wired (pp. 28–29).
  • Shunts. The 2094-BSP2 module is replaced by 2198-Rxxx resistors wired to the DC-bus supply; only the 2198-R004 may be mounted inside the enclosure (pp. 15, 29).
  • Inverter sizing by output current. Table 9 (p. 24) pairs each Kinetix 6000 module with a Kinetix 5700 inverter, for example 2094-BM01-S (6.1 A rms) with 2198-D020-ERS3 (8.0 A rms) and 2094-BM05-S (34.6 A rms) with 2198-S086-ERS3 (43.0 A rms). Kinetix 5700 inverters need a properly sized DC-bus power supply (p. 24, note 2).
  • Motors can stay, with conditions. 1326AB, MPL/MPM/MPF/MPS and RDB motors, LDC linear motors and MPAS/MPAR/MPAI/LDAT actuators remain usable, but feedback compatibility restrictions apply (p. 11). 1326AB resolver motors need a third-party resolver converter and a custom motor file (p. 14).
  • Feedback kits. The 2198-K57CK-D15M kit accepts Hiperface, EnDat, AqB and sin/cos (p. 17). The 2198-H2DCK kit converts Hiperface to DSL when a dual position loop is needed (p. 18).
  • Cables. Only the 2090-CxBM7DF motor cables — 2090-CPBM7DF power and 2090-CFBM7DF feedback — are shared between the two systems (pp. 18, 22). Feedback cables are limited to 90 m with absolute encoders, 30 m with incremental encoders and 75 m with EnDat (p. 18); Ethernet cables to 100 m, and shielded cable is required (p. 19).
  • Size. In most cases Kinetix 5700 needs less panel space and fits the Kinetix 6000 space (p. 19).
  • Logix Designer. The DC-bus supply has to be added to the I/O Configuration (p. 41).

The guide includes a ten-item checklist (Table 1, pp. 11–12): rotary motor compatibility, linear motor and actuator compatibility, 24 V DC for brakes, power for digital and registration inputs, I/O terminations, hardware enable inputs, STO, input power components, precharge protection relays, and DC common-bus capability.

Kinetix 300 to Kinetix 5100 (2198-RM004C)

Each Kinetix 300 operating mode has a Kinetix 5100 counterpart (p. 7):

Kinetix 300 Kinetix 5100
Analog Current T
Analog Velocity S
Indexing PR
Master Gearing, Step and Direction PT
EtherNet/IP External Reference I/O mode (AOP and AOI)
  • Digital I/O. Twelve inputs in three isolated groups become ten inputs (eight standard, two high-speed) on one common; registration is only on inputs 9 and 10. Indexes increase from 32 to 99 (pp. 20, 22). Digital outputs go from five to six (p. 23).
  • Motors and cables. Only Kinetix MP and TL motors run on both drives; MP motors with resolver feedback do not run on Kinetix 5100 (p. 29). MP and TL/TLY cables are reusable; for TL/TLY, remove the 2090-DANFCT drive-end connector and use the 2198-K51CK-D15M kit (pp. 49–50).
  • Short-circuit current rating drops from 100,000 A on Kinetix 300 to 5,000 A on Kinetix 5100 (pp. 16–18); review the upstream protection.
  • Network. Kinetix 300 supports star topology only (a 1783-ETAP is needed for linear or ring); Kinetix 5100 has two ports for linear, ring and star (p. 35).
  • Control from the PLC. Kinetix 5100 can be controlled through AOIs in I/O mode, by explicit messaging from MicroLogix, Micro800 or third-party controllers, or standalone by pulse train, analog or digital I/O (pp. 60–62). The guide gives four conversion scenarios: analog to analog, indexing to PR, gearing/step-direction to PT (maximum pulse frequency up from 2 MHz to 4 MHz), and External Reference to I/O mode (pp. 64–70).

Kinetix 350 to Kinetix 5300 (2198-RM005B)

  • Both are configured and programmed in Studio 5000 (pp. 5–6); Kinetix 5300 needs v33.00 or later (p. 46).
  • Brake. Kinetix 5300 powers brakes up to 2.25 A directly; do not wire a customer supply to this brake circuit, and the external relay can often be removed (p. 22).
  • STO. The 6-pin plug becomes a 10-pin connector with different pinouts (pp. 33–34).
  • Cables and feedback. MP power and feedback cables are reusable (pp. 25, 39); where flying-lead cables were used, replace the kit with the 2198-K53CK-D15M (p. 39).
  • Similar size, for example 2097-V31PR0-LM (238 × 68 × 185 mm) to 2198-C1004-ERS (215 × 50 × 200 mm) (p. 10). Motor power moves from the front to the bottom of the drive (p. 11).

Ultra3000 to Kinetix 5100 or Kinetix 5300

To Kinetix 5100 (2198-RM003B). Analog Current, Analog Velocity, Analog Position, Preset, Follower and Indexing modes all have counterparts (T, S, PT, PR…); Host Command moves to explicit messaging and DeviceNet to I/O mode with AOIs (p. 9).

  • Serial or DeviceNet communication becomes USB for configuration and EtherNet/IP for control; RSNetWorx for DeviceNet is no longer needed (pp. 13, 40, 88).
  • Inputs go from eight (sinking only) to ten, sinking or sourcing; outputs from four to six (pp. 13–14).
  • 1326AB and F/H/N/Y-series motors are not supported on Kinetix 5100; MP motors (except resolver types) and TLY-A…-H motors run on both; Ultra3000 does not run TL motors (p. 34).
  • Maximum cable length drops from 90 m to 50 m (MP Hiperface, TLP) or 30 m (TL/TLY, MP incremental) (p. 14). Maximum ambient temperature drops from 55 °C to 50 °C (p. 11).
  • Breakout boards, the resistive brake module (RBM) and auxiliary encoders are not shared (p. 35).

To Kinetix 5300 (2198-RM006A), for SERCOS drives. Fiber-optic SERCOS becomes dual-port EtherNet/IP; Studio 5000 v33.00 or later is required (p. 13). The Ultra3000's optional 5 V or auxiliary supply is replaced by a required 24 V DC supply (pp. 15–16). Six dedicated inputs become four configurable inputs (p. 16). Existing feedback cables work with the 2198-K53CK-D15M kit (p. 35). In most cases Kinetix 5300 is smaller and fits the Ultra3000 space (p. 15).

Where the drive size needs a second look

The replacement on a Rockwell product page does not always match the output-current table in the migration guide. Examples from the end-of-life lookup:

  • 2094-AM05-S: the product page lists 2198-D012-ERS3; Table 9 of 2198-RM002B pairs it with 2198-S086-ERS3 by its 34.6 A rms output.
  • 2098-DSD-075: the product page lists 2198-E2075-ERS; Table 8 of 2198-RM003B pairs it with 2198-E2055-ERS.
  • 2099-BM09-S (96 A rms continuous, 2099-UM001G p. 150): the page lists 2198-S160-ERS3, rated 85 A rms (2198-RM002B p. 24).
  • 2098-DSD-HV220-SE (33.2 A rms): the page lists 2198-C4075-ERS, rated 27.5 A rms (2198-RM006A p. 20).

2198-RM002B recommends sizing the drive, the DC-bus supply and the shunt in Motion Analyzer against the real load (pp. 6, 24, 37).

A TDL case: P&G Dong An packing lines

From 2024 to 2026 TDL replaced 24 discontinued servo drives with Kinetix 5300 on five packing machines at P&G Vietnam's Dong An plant:

Machine Old drive New drive
Labeller 11 × Ultra3000 11 × Kinetix 5300
Bottle filler Ultra3000i Kinetix 5300
Mespack 1 pouch packing machine Kinetix 300 4 × Kinetix 5300
Mespack 2, Mespack 440 Kinetix 350 4 × Kinetix 5300 each

Parameters of the old drives were backed up before removal, and the axes were set up again as integrated motion on EtherNet/IP axes in the new program. Kinetix 350 and Ultra3000 follow the Kinetix 5300 path of 2198-RM005B and 2198-RM006A; the Kinetix 300 and Ultra3000i drives also went to Kinetix 5300 rather than Kinetix 5100, controlled by integrated motion. Details: P&G Dong An packing line project.

Before replacing the drive

  1. Upload and save the controller program and the current network configuration files; if no current copy exists, upload it first (2198-RM002B p. 6; 2198-RM005B p. 7).
  2. Record the drive and motor catalog numbers, feedback type, cable lengths and the I/O, STO and brake wiring of every axis; label every connection before disconnecting (2198-RM004C p. 11; 2198-RM005B p. 7).
  3. Size the new drive in Motion Analyzer; check which motors can stay and which feedback kits are needed.
  4. Check the Studio 5000 version, EtherNet/IP modules and switches against the new drive's requirements.
  5. Add the 24 V DC supply, relays, shunt resistors and line filters required by the new drive family to the bill of materials.
  6. For SERCOS systems: plan the axis reconfiguration in Logix Designer and review the tuning (2198-RM002B pp. 41–42).

Frequently asked questions

What replaces Kinetix 6000?

Kinetix 5700, under migration guide 2198-RM002B. Inverters are chosen by output current from Table 9 (p. 24), plus a 2198-Pxxx DC-bus power supply in place of the Kinetix 6000 power rail and IAM.

Should Kinetix 300 go to Kinetix 5100 or Kinetix 5300?

Kinetix 300 has a guide to Kinetix 5100 (2198-RM004C), whose PR mode replaces Kinetix 300 indexing. Kinetix 350, the integrated-motion drive, has a guide to Kinetix 5300 (2198-RM005B).

Can the existing motors stay?

Many can, but each type has to be checked. For example, only MP and TL motors run on both Kinetix 300 and Kinetix 5100, and resolver MP motors do not (2198-RM004C p. 29); Kinetix 5100 does not support the 1326AB and F/H/N/Y-series motors used with Ultra3000, and the only TL-family motors Ultra3000 runs are TLY-A…-H (2198-RM003B p. 34).

What extra power supply does the new drive need?

Kinetix 5700 needs a customer-supplied 24 V DC supply for control power, digital inputs and brakes (2198-RM002B pp. 12, 19). Kinetix 5300 also uses 24 V DC (2198-RM005B p. 23). Kinetix 5100 200 V-class drives take control power from one incoming AC phase; 400 V-class drives use 24 V DC (2198-RM004C pp. 16, 28–29).

Can an Ultra3000 SERCOS drive move to Kinetix 5100?

Per 2198-RM006A, Ultra3000 SERCOS drives are pointed to Kinetix 5300 (Figure 1 also shows Kinetix 5500); analog, indexing and DeviceNet drives are pointed to Kinetix 5100 under 2198-RM003 (2198-RM006A p. 6).

Sources

  • Rockwell Automation, 2198-RM002B-EN-P, Migration Guidelines: Kinetix 6000 Servo Drive to Kinetix 5700 Servo Drives, 03/2022 — pp. 6, 11–22, 24, 28–29, 37, 41–42
  • Rockwell Automation, 2198-RM004C-EN-P, Kinetix 300 to Kinetix 5100 Servo Drive Migration Guide, 03/2022 — pp. 7, 11, 13, 16–18, 20–23, 28–29, 34–35, 44, 49–50, 60–70
  • Rockwell Automation, 2198-RM005B-EN-P, Kinetix 350 to Kinetix 5300 Servo Drive Migration Guide, 01/2022 — pp. 5–7, 10–11, 19, 21–23, 25, 27, 33–34, 39, 46
  • Rockwell Automation, 2198-RM003B-EN-P, Ultra3000 to Kinetix 5100 Servo Drives Migration Guide, 11/2020 — pp. 9, 11, 13–14, 34–35, 40–41, 88
  • Rockwell Automation, 2198-RM006A-EN-P, Ultra3000 Digital Servo Drives to Kinetix 5300 Servo Drives Migration Guide, 12/2020 — pp. 6, 13, 15–17, 20, 35, 53
  • Rockwell Automation, 2094-UM002I-EN-P, Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual, 12/2022 — p. 23
  • Rockwell Automation, 2099-UM001G-EN-P, Kinetix 7000 High Power Servo Drive User Manual, 12/2022 — p. 150
  • Rockwell Automation, rockwellautomation.com product page for each catalog number (lifecycle status, discontinued date, replacement)

Read 27 October 2026. This article paraphrases the sources and does not quote them; read the original documents before designing or working on a system. Links open the latest version in Rockwell's literature library; page numbers refer to the revision named in this article.