Home › End-of-life lookup › Ultra5000 intelligent positioning drives (2098-IPD)

Ultra5000 Intelligent Positioning Drive 15 kW DeviceNet 2098-IPD-150-DN (discontinued)

Rockwell lifecycle statusDiscontinued 01/04/2013 (read on 5 November 2026)
ReplacementTDL proposal (Rockwell names no catalog number)

The Rockwell Product Lifecycle Status tool (read 05/11/2026, description "Ultra 5000 Servo Drive") shows Discontinued 01/04/2013 with replacement category "No planned RA replacement" and no replacement catalog number (N/A). No Rockwell migration guide for Ultra5000 was found; 2198-RM003B covers Ultra3000 drives only. See the TDL proposal below. TDL proposal (not a Rockwell statement): migrate to Kinetix 5100, the family Rockwell recommends for Ultra3000 and Kinetix 3. The Ultra5000 current ratings for this size are in Appendix A of 2098-IN001E, which could not be read; the manual gives 15 kW (2098-IN001E p. 2-10). Starting candidate 2198-E2075-ERS (49.0 (69.3) / 78.0 (110.3) A rms (0-pk) continuous/peak, 2198-RM003B Table 8, p. 15), the drive Table 8 pairs with the Ultra3000 2098-DSD-150 (45.9 (65) / 106.0 (150) A rms (0-pk) continuous/peak). Table 3 (p. 10) rates 2198-E2075-ERS at 7.5 kW, so check the motor's continuous and peak current from its nameplate. Table 8 lists a peak of 78.0 A rms for 2198-E2075-ERS, below the 106.0 A rms peak of 2098-DSD-150, while Table 3 (p. 10) lists 127.49 A rms; confirm the peak, and consider 2198-E2150-ERS (78 / 162 A rms continuous/peak, 2198-RM003B Table 3, p. 10), rated 15 kW. Confirm the load and the motor/feedback compatibility (motor may need replacing) before ordering. The Ultra5000 runs user programs written in C with the Motion Library (2098-IN001E p. P-3); none of the Kinetix 5100 control modes in 2198-RM003B Table 2 (p. 9) runs user C code, so the motion program must be rewritten, as Kinetix 5100 PR-mode indexing (99 program registers) or as Logix motion in a controller over EtherNet/IP (IO mode). This is not a drop-in replacement. Kinetix 5100 uses EtherNet/IP for control; the guide mentions no DeviceNet port on it (2198-RM003B Table 7, p. 13), so the DeviceNet link must be re-engineered.

Key data

FamilyUltra5000 Intelligent Positioning Drive, programmed in C with the Motion Library (2098-IN001E p. P-3); DeviceNet version (2098-IN001E p. 1-4)
Input voltage100–240 V AC, 50/60 Hz, three phase (L1, L2, L3) (2098-IN001E pp. 2-10, 2-12)
Continuous output power15 kW (2098-IN001E p. 2-10)
I/O16 digital inputs, 8 digital outputs (7 transistor, 1 relay), 2 analog inputs, 2 analog outputs (2098-IN001E pp. 2-20 to 2-24)

Lifecycle status changes over time: confirm the current status on the Rockwell product page or in the Product Compatibility and Download Center before ordering.

Related services: Lifecycle review and spare parts Rockwell Automation upgrades

Other catalog numbers in this family: Ultra5000 intelligent positioning drives (2098-IPD)

2098-IPD-005 2098-IPD-005-DN 2098-IPD-010 2098-IPD-010-DN 2098-IPD-020 2098-IPD-020-DN 2098-IPD-030 2098-IPD-030-DN 2098-IPD-075 2098-IPD-075-DN 2098-IPD-150 2098-IPD-HV030 2098-IPD-HV030-DN 2098-IPD-HV050 2098-IPD-HV050-DN 2098-IPD-HV100 2098-IPD-HV100-DN 2098-IPD-HV150 2098-IPD-HV150-DN 2098-IPD-HV220 2098-IPD-HV220-DN

Sources